P0743 BMW Fault Code
Check P0743 OBD Fault Code ReasonVariable Cam Timing Over-advanced (Bank 1) The comprehensive component monitor (CCM) monitors the VCT position for an over-advanced camshaft timing.
The test fails when the camshaft timing exceeds a maximum calibrated value or remains in an advanced position.
BMW cam timing improperly set No oil flow to the VCT piston chamber Low oil pressure VCT solenoid valve stuck closed Camshaft advance mechanism binding (VCT unit) P0743 DTC is a check of the VCT unit.
P0743 Code Symptoms :
The P0743 Check Engine lamp is perhaps the most troubling of lights because it could mean so many different things, from you didn't screw the gas cap on tightly enough to look out for pistons flying through the hood and into the stratosphere. The easiest way to find out what this light is telling you is to hook your vehicle up to a scan tool. P0743 diagnostic tool looks a little like an oversized calculator and plugs into a communication port inside the car. After you instruct it to perform the scan, it speaks with your car's computers to find out exactly what's prompting the light to turn on.
Diagnosis And Repairing P0743
P0743 OBD2 may also be triggered by faults earlier down the line. For example, a dirty MAF sensor might be causing the car to overcompensate in its fuel-trim adjustments. As a result, oxygen sensors are likely to report fuel mixture problems.
How to fix P0743 code ?
- Erratic camshaft position due to low oil pressure
- Engine Control Module (ECM)
- Camshaft advance mechanism binding (VCT unit)
- Three way catalyst converter Bank 1
As the engine heats up and combustion becomes easier and more complete, the PCM will command the idling control valve to increase the amount of air entering the engine to suit the changing conditions.
However, when the load on the engine changes, say, when some electrical consumers or other systems are either turned on or off, the PCM adapts the signal voltage to the idle control valve to ensure that the idling speed remains stable, and at the RPM specified by the manufacturer.